626 Series Two-way Ventilator

The 626 Series Two-way Ventilator scoops air in or out for complete control and comfort in the engineer compartment. A one-piece frame design gives increased strength and eliminates the need for screens. It has a completely hingeless design and is easy to operate for maximum cab. It "closes tight and stays tight".

No image

629-000 Cab Awning

The 629-000 Cab Awning is designed to shade the engineer compartment from sun and adverse weather. When not needed, our Cab Awning snaps to a folded position with a pull from the inside. Just as importantly the unique design allows the unit to close upon contact, providing the operator with added safety.

wabtec westinghouse air brake 650 Series Windshield Wings

650 Series Windshield Wings

The 650 Series Adjustable Windshield Wings are located on each side of the cab exterior to provide clear vision for the operator and crew.

No image

651 Series Full-length Mirrors

651 Series Full-length Mirrors are located on each side of the cab exterior to provide clear vision for the operator and crew. Full-length mirrors come in two sizes and offer wider vision than previous models. The "Rapid-Adjust" feature on the 651-101R & L and 107R & L allows quick realignment of mirror angles for optimum vision.

No image

682 Series Pressure Check Valves

An inline one way pressure check valve; 75 psi breaking pressure.

wabtec westinghouse air brake Graham White 686 Series Self-Actuating Drain Valve

686 Series Self-Actuating Drain Valve

The 686 Series Self-Actuating Drain Valve, commonly known as the Drain-matic, is designed to exhaust liquid contaminants from the locomotive air reservoir without any pneumatic or electrical signals. The valve works on the Bernoulli principle whereby a steel disc moves and seats upon a steel valve body. Like other GW drain valves, an integral drain/shut-off feature to manually exhaust contaminants, or disarm the valve as desired, is available. Each 686 Series Self-Actuating Drain Valve is supplied with a flange-type mounting bracket for ease of installation on AAR type reservoirs. A heater thermostat assembly is available in several voltages for severe weather applications to prevent freezing.

No image

696 Series of Two Way Check (Shuttle) Valve

The 696 Series of Two Way Check (Shuttle) Valve is manufactured with a heavy-duty corrosion-resistant iron housing. It is equipped with a total of three ports, two inlets and one outlet. This porting allows for quick change-over from desired inlet conditions to the outlet valve side. The check aspect assures that only the desired inlet signal is transmitted to the outlet port. The 696 has a custom flange face to adapt to specific air brake manifolds. All are enhanced with our in-line cartridge design that eliminates the need to break any pipe connections resulting in a significant reduction in costly out-of-service time during maintenance. The check valve cartridge is designed with or without a spring at customer request and a stainless steel shuttle that seals on an o-ring to eliminate compressed air leakage. Several configurations with orifices are available and marked for quick reference. In addition, the GW 5998-050 Series Orifice Adapter can be used with the 998 style check valve to control flow and eliminate the need for a second in-line check valve.

No image

699 Series One Way Check Valves

The 699 Series One Way Check Valves are made with corrosion-resistant cast aluminum. The 699 has a custom flange face to adapt to specific air brake manifolds. Each have a soft "O" ring style leak proof sealing and an in-line cartridge. The cartridge design allows for in-line servicing resulting in a significant reduction in costly out-of- service time during maintenance. The check valve cartridge is designed with a spring for positive action and stainless steel shuttle that seals on an "O" ring to eliminate compressed air leakage. Several configurations with orifices are available and marked for quick reference.

No image

706-000 Air Gauge and Pressure Switch Tester with Holster

The 706-000 Air Gauge and Pressure Switch Tester with Holster was designed to facilitate testing of the locomotive analog air gauges every 92 days as required by the FRA (Federal Railroad Administration). Its light weight and design allow it to be carried anywhere for easy use. Typically, the gauge must be removed from the locomotive and tested on a dead weight tester resulting in out-of- service time. W ith the 706 Tester the gauges are tested in place and only removed if calibration is required. The tester operates with replaceable CO2 cartridges and is a proven "one of a kind" hand-operated, self-contained portable unit. In addition, the 706 Tester is designed to test an assortment of pressure switches when the GW quick disconnect fitting is used. The tester includes an assortment of probes for testing GW and Prime gauges.
 
12 Pack Of Replacement CO2 Cartridges -- 706-020

wabtec westinghouse air brake 711 Series Conductor Valve

711 Series Conductor Valve

The 711 Series Conductor Valve is identified in the Rail Industry as a high capacity manually operated lever valve that can be used as a quick exhaust valve. It is most frequently used to quickly exhaust brake pipe air to atmosphere when required by the operator.  Customarily furnished with 1 1/4" NPT inlet and outlet connections, it is made of corrosion resistant iron and has leak proof sealing. The unique twin spring balanced disc design makes it both easy to manually actuate to the secured open position and assures complete shut of f when manually actuated to the closed position.

wabtec westinghouse air brake 785 & 786 Series 4 inch Pressure Gauges

785 & 786 Series 4 inch Pressure Gauges

Graham-White Custom Pressure Gauges have long been the standard technology for both the heavy rail and rail transit industries. From a pressure stand point, our unique Duplex Pressure Gauge series is an extraordinary single gauge that delivers two separate pressure readings simultaneously. This dual function does the work of two single gauges, requires half the panel space, and costs less. The 785 & 786 Series 4" Duplex Air Gauges are designed with high quality bronze bourdon tubes and precision phosphor bronze movements for optimum performance and reliability. Black or green dials with white numerals (0-160 and 0-200 PSI scale) are standard. An integral quick disconnect and test feature makes all GW gauges easy to install within your control stand or console and inspect in place using the GW 706-000 Air Gauge and Pressure Switch Tester. All gauges can be removed for servicing without breaking any pipe connections. An assortment of GW "Quick Disconnect" Test Fittings are available for quick and easy testing of stand-alone air gauges and pressure switches.

No image

793 & 794 Series 4.5 inch Gauges

793 & 794 Series 4 1/2" Duplex Air Gauges are designed with high quality bronze bourdon tubes and precision phosphor bronze movements for optimum performance and reliability . Black or green dials with white numerals (0-160 and 0-200 PSI scale) are standard. Other scales, i.e. BAR, Kg/Cm2, Kilo Pascal scales are available upon request to measure a variety of air pressures, i.e. MR, BP , BC and MRE. Down or side connection mounting assembly with quick disconnect and an integral test feature makes it easy to install within your control stand and inspect in place without breaking any air connections using the GW 706-000 Gauge and Pressure Switch Tester. The case and lens cover is made of molded plastic with glass and/or Lexan. Gauge complexes with AFI or AFM Indicators are available upon request.

No image

796-100 Series Air Flow Indicators

A Series of 796-100 Air Flow Indicators with adjustable base are available to measure air system leakage across a 19/64" orifice using a pressure dif ferential (psi) scale. Green or black dials are available with down or side-mounting assembly . An integral quick "disconnect and test" feature allows for periodic inspection in place without breaking any air connections while using the GW 706-000 Gauge and Pressure Switch Tester. A red indicator light and adjustable AFM reference pointer are included. AFI are available in individual housing if console or control stand mounting is not possible. 19/64" orifices and adapters are available and illustrated in GW's miscellaneous section.

No image

796-600 Series Air Flow Method (AFM) Indicators

A Series of AAR approved 796-600 Series Air Flow Method (AFM) Indicators with adjustable base are available to measure air system leakage across a 19/64" orifice using an airflow (cfm) scale. Green or black dials are available with down or side-mounting assembly . An integral quick disconnect and test feature allow for periodic inspection in place without breaking any air connections while using the GW 706-000 Gauge and Pressure Switch Tester. A red movable reference pointer is available on the 796-630 Series. AFM Indicators are available in individual housing if console or control stand mounting is not possible.

Wabtec Corporation D77 Terminal Lug

8133497-FCW D77 Terminal Lug

  • CRIMP TESTED AND APPROVED BY EXTERNAL LAB
  • FAI with existing customers approved, and parts in service
  • COMING SOON:  Ability to order as complete “Kits” (6 Lugs)
  • In stock and available for immediate delivery

No image

818 Series

Compressed Air Filter with an elongated centrifugal passage that spins the air and separates the liquids from it. This centrifugal passage has the unique ability to remove extremely high amounts of bulk liquids and to maintain separation efficiency throughout its full operating flow range.

wabtec westinghouse air brake 824 Series Dual Stage Filters

824 Series Dual Stage Filters

The 824 Series Dual Stage Filters combine the high efficiency performance advantages of our unique Centrifugal Separation method coupled with an extended surface, sub-micron Coalescing Element, together with one of GWs' dependable automatic drains. In combination, the end result is that heavy bulk liquids are removed by centrifugal motion. Oil varnish and water aerosols .03 micron and larger are coalesced. Abrasive particles above .3 microns are retained. Accumulated liquid contaminates are automatically expelled by the trouble free operation of the GW automatic drain. Without these contaminants to contend with, your auxiliary equipment (i.e. sanding, horn, bell, miscellaneous air valves and safety related brake equipment) will operate more reliably. In addition, contamination in the form of water, solids and oil varnish, if not removed properly, will lead to unscheduled maintenance, down time and unnecessary added costs. The 824 Series Air Dual Stage Filters are available with a number of configurations and a number of different automatic drain valves. Drain valves can be either total electric or air piloted.

No image

849 Illuminated Console or Panel Series Air Gauges

The 849 Illuminated Console or Panel Series Duplex Air Gauges are designed with high quality bronze bourdon tubes and precision phosphor bronze movement for optimum performance and reliability . Black, green, white, silver dials and an assortment of scales, i.e. PSI (0-160 and 0-200 models), BAR, Kg/Cm2, Kilo Pascal, etc. are available to measure a variety of air pressures, i.e. MR, BP , BC and MRE. Air connections are on the back of the gauge case assembly . An integral test feature makes it easy to install within your console and inspect in place without breaking any air and/or electrical connections while using the GW 706-000 Gauge and Pressure Switch Tester. The gauge and cover assemblies are made of molded, break resistant, polycarbonate.

wabtec westinghouse air brake 853-003 Air Start Valve (Relay Valve)

853-003 Air Start Valve (Relay Valve)

A two stage 1 1/2" relay valve commonly used in air start systems for diesel engines. The first stage is a low flow stage to build pressure followed by full flow "non restricted" stage for rapid delivery of air.

wabtec westinghouse air brake Graham White 975 Series Final Filter

975 Series Final Filter

The 975-075 Final Filter is a lightweight inline option. The easy-to-change filter element, with 99.9% efficiency, collects solid particulate 10 micron and greater. The Final Filter can be used for inline filtration or after a pressure swing regenerative air dryer to collect solid particulate. An integral manual drain is located on the sump for quick inspection or drainage of collected liquid water.